You might need to set specified ports on the servers in the CMC.  To do this:

 

1.  Log in to the CMC.

2.  Go to Servers.

3.  Edit the properties of the following servers to set a specified port in order to be able to save from Crystal:

    

     Crystal 2013 Report Application Server

     Crystal Processing Server

     Input File Repository Server

 

Set the ports to something between 6411 and 6499 (this range will avoid any of the ports that are automatically explicitly set for the CMS, SIA, and WACS.)

 

4.  Restart these three servers.  If any of them don't come up due to a port conflict, restart the SIA.

 